Battery Backup Runtime Calculator: How Long a Home Battery Lasts

See how many hours a home battery can keep your house running during an outage. Enter the battery's capacity, your average load and how charged it is when the power goes out; the tool allows for the reserve you keep and inverter losses.

Battery Backup Runtime Calculator

Total for all batteries installed.

A fridge, lights, Wi-Fi and a TV average roughly 300–600 W. Central AC adds 3,000 W or more while running.

Batteries used for daily savings may not be full.

More optionsFewer options

Some owners keep a reserve for a second outage.

Losses converting stored DC to household AC.

Your result

Estimated runtime 13.7 hours

Days
0.6
Energy delivered
10.9 kWh

At that average load the battery would last about 13.7 hours with no solar recharge, delivering 10.9 kWh.

Educational estimate only. Not financial, tax or legal advice.

Runtime at different loads
010203040300300500500800800120012002000200035003500Average load (W)300 · Hours: 36.5 hours36.5500 · Hours: 21.9 hours21.9800 · Hours: 13.7 hours13.71200 · Hours: 9.1 hours9.12000 · Hours: 5.5 hours5.53500 · Hours: 3.1 hours3.1
  • Hours
View as table
Average load (W)Hours
30036.5 hours
50021.9 hours
80013.7 hours
12009.1 hours
20005.5 hours
35003.1 hours

Runtime by load

Average load (W)HoursDays
20054.72.3
30036.51.5
50021.90.9
80013.70.6
1,00010.90.5
1,5007.30.3
2,0005.50.2
3,5003.10.1
5,0002.20.1

Compare battery size and starting charge

ResultA Your inputsB Twice the capacityC Starts half fullDifference (B − A)
Runtime13.7 hours27.3 hours6.1 hours+13.7 hours

Results update as you type. Without JavaScript you see the worked example below.

How to use it

  1. Enter the battery capacity in kWh from the spec sheet or your quote.
  2. Enter the average load in watts you expect during the outage.
  3. Set the charge when the outage starts, such as 100% or a lower level if you use the battery daily.
  4. Under advanced, set the reserve you keep unused and the inverter efficiency.
  5. Read the runtime in hours and days, then check the runtime-by-load table and the scenarios.

A battery backup runtime calculator divides the energy a battery can actually deliver by your average load. With the defaults, a full 13.5 kWh battery with a 10% reserve and 90% inverter efficiency delivers about 10.9 kWh, which runs an 800 W average load for about 13.7 hours, or 0.6 days, with no solar recharge.

How to use the battery backup runtime calculator

  1. Battery capacity. The kWh rating from the spec sheet or quote. Default 13.5 kWh, the median home battery installed with solar in 2025 (LBNL, 2026 (opens in a new tab)).
  2. Average load during the outage. The average watts your backed-up circuits draw over the outage, not the peak. Default 800 W.
  3. Charge when the outage starts. 100% if the battery sits full for backup; lower if you cycle it daily. Default 100%.
  4. Advanced: Reserve you keep unused (10%) and Inverter efficiency (90%).

You get the estimated runtime in hours, the same figure in days, and the energy delivered. A bar chart shows runtime at 300, 500, 800, 1,200, 2,000 and 3,500 W, and a runtime-by-load schedule (200 W to 5,000 W, hours and days) can be downloaded as CSV. The scenario table compares your inputs, twice the capacity, and the same battery starting half full.

How the calculation works

Energy delivered (kWh) = capacity × (starting charge − reserve) × inverter efficiency
Runtime (hours)        = energy delivered × 1,000 ÷ average load (W)
Runtime (days)         = hours ÷ 24

Assumptions that match the code:

  • Constant average load. Real loads cycle (a refrigerator compressor turns on and off), but the average is what drains the battery.
  • No solar recharge during the outage, a worst case for nights and storms.
  • The reserve is untouched. If the starting charge is at or below the reserve, runtime is zero.
  • 90% inverter efficiency is a round, conservative figure; PVWatts uses 96% for solar inverters by default (PVWatts API (opens in a new tab)), and battery systems vary.

Worked example

Default inputs: 13.5 kWh, 800 W, starting at 100%, 10% reserve, 90% efficiency.

  • Energy delivered: 13.5 × (1.00 − 0.10) × 0.90 = 10.9 kWh.
  • Estimated runtime: 10,935 Wh ÷ 800 W = 13.7 hours, or 0.6 days.

The default scenario table shows 13.7 hours for your inputs, 27.3 hours with twice the capacity (27 kWh) and 6.1 hours if the battery starts half full.

Second example, two batteries cycled daily: 27 kWh, a 1,200 W average load, 80% charge when the outage starts and a 20% reserve.

  • Energy delivered: 27 × (0.80 − 0.20) × 0.90 = 14.6 kWh.
  • Runtime: about 12.2 hours (0.5 days). Starting full instead would give about 24.3 hours.

Runtime of a 13.5 kWh battery by load (default settings)

Average loadHoursDays
200 W54.72.3
300 W36.51.5
500 W21.90.9
800 W13.70.6
1,000 W10.90.5
1,500 W7.30.3
2,000 W5.50.2
3,500 W3.10.1
5,000 W2.20.1

Load matters more than anything else. Cutting the average from 1,500 W to 500 W triples runtime.

What your result means

If the runtime covers the outages you usually see, the battery fits your needs. If not, you can trim loads, add capacity, keep a higher charge before storms, or add solar recharge. Our home battery backup guide explains partial-home backup panels, which are the main way to keep the average load low.

To size a battery from an appliance list instead, use the solar battery size calculator. If outages are long and frequent, compare costs with the battery vs generator calculator.

Rules that change the answer

  • Daily cycling plans. Time-of-use and net billing plans reward discharging every evening, which leaves less in the battery at night. See are solar batteries worth it and set a storm reserve when outages are forecast.
  • Islanding. Whether solar can recharge the battery during an outage depends on the inverter and wiring. Ask your installer.
  • Regional outage risk. Hurricanes in Florida and winter storms in Texas can mean multi-day outages; see solar panels in Florida and solar panels in Texas.
  • Installation codes. NFPA 855 and local codes govern where and how much storage can be installed (NFPA (opens in a new tab)).

Common mistakes

  • Entering peak watts instead of average watts.
  • Assuming the battery is always full when the outage hits.
  • Forgetting the backup reserve and inverter losses.
  • Backing up the whole house, including AC and an electric water heater, and expecting essentials-only runtime.
  • Counting on solar recharge without confirming the system can island.

Limits of this calculator

This is an educational estimate. It uses a constant load and fixed efficiency, and it ignores temperature effects, battery aging and power limits on how much can run at once. Your battery's app and the manufacturer's spec sheet give the most accurate picture of real runtime.

Frequently asked questions

How long will a 13.5 kWh battery last in an outage?

With the defaults, a full 13.5 kWh battery with a 10 percent reserve and 90 percent inverter efficiency delivers about 10.9 kWh, enough for 13.7 hours at an average 800 W load. At 300 W of essentials it lasts about 36.5 hours; at 2,000 W, about 5.5 hours.

What is a typical average load during an outage?

It depends on what is on backed-up circuits. A refrigerator, lights, internet and phone charging often average a few hundred watts, while running central air or an electric water heater can push the average past 2,000 W. Your battery app or a utility smart-meter history can show your real average.

Why does the tool subtract a reserve?

Many home batteries let you set a backup reserve, a share of capacity kept for emergencies or to protect the battery. It is not available during the outage in this calculation. The default is 10 percent; set it to 0 if your battery lets you use the full capacity.

What if my battery is not full when the outage starts?

Runtime drops in proportion. If you use the battery every day for time-of-use savings, it may be half empty in the evening. With the defaults, starting at 50 percent cuts runtime from 13.7 to about 6.1 hours, which is why many owners raise the reserve before a forecast storm.

Does solar extend the runtime?

It can, if your system is designed to keep the panels running and recharge the battery while the grid is down. This calculator assumes no solar recharge, a safe worst case for nights and stormy days. Use the battery size calculator to model daily solar recharge over multi-day outages.

Why is the energy delivered less than the battery's capacity?

The inverter that turns stored DC power into household AC power loses some energy, about 10 percent at the default 90 percent efficiency. Combined with the 10 percent reserve, a 13.5 kWh battery delivers about 10.9 kWh to your appliances.

Is doubling the battery the same as doubling runtime?

Yes, at the same load. The scenario table shows the default battery's 13.7 hours rising to about 27.3 hours with twice the capacity. Peak power is a separate limit, though; two units can also run more appliances at once.

Sources

Checked against these sources. Dates show when each was last reviewed.

  1. U.S. Distributed Solar and Storage: 2026 Data Update (opens in a new tab), Lawrence Berkeley National Laboratory (as ofOctober 2026)
  2. PVWatts V8 API documentation (inverter efficiency default) (opens in a new tab), National Laboratory of the Rockies (formerly NREL) (as ofOctober 2026)
  3. NFPA 855: Standard for the Installation of Stationary Energy Storage Systems (opens in a new tab), National Fire Protection Association (as ofOctober 2026)
  4. Homeowner's Guide to Going Solar (opens in a new tab), U.S. Department of Energy (as ofOctober 2026)
  5. Solar Power for Your Home (opens in a new tab), Federal Trade Commission (as ofOctober 2026)